{"id":12954,"date":"2021-11-16T08:45:44","date_gmt":"2021-11-16T08:45:44","guid":{"rendered":"https:\/\/www.inprogroup.net\/productos\/gp-m-ge\/"},"modified":"2026-10-13T12:28:38","modified_gmt":"2026-10-13T12:28:38","slug":"gp-m-ge","status":"publish","type":"productos","link":"https:\/\/www.inprord.com\/en\/products\/gp-m-ge\/","title":{"rendered":"04. GP-H-GE High Pressure"},"content":{"rendered":"<h2><strong>OIL TRANSFER PRESSURE UNITS- HIGH PRESSURE-\u00a0 twin system\u00a0<\/strong><\/h2>\n<h3><strong>GE: 2 pumps<\/strong><\/h3>\n<p>Inpro pressure units are equipment used to transfer liquid fuel such as diesel or HVO from a main tank to different consumption points through the pressurization of a line, for the supply of machinery that requires these fuels, such as generators (power generators) or burners for boilers in buildings.<\/p>\n<h6><span style=\"color: #ffffff;\">.<\/span><\/h6>\n<p>There are several sizes and configurations of equipment, in which the flow rate that can control the equipment can vary, the maximum pressure at which they can work, with the possibility of redundancy in some components, and other parameters such as the type of power supply.<\/p>\n<h6><span style=\"color: #ffffff;\">.<\/span><\/h6>\n<p>Twin units that duplicate critical components to increase reliability.<\/p>\n<h6><span style=\"color: #ffffff;\">.<\/span><\/h6>\n<h3><strong>\u00a0Application area e<\/strong><strong>xample<\/strong><\/h3>\n<p><strong>Small units (from 30l\/h to 1,500l\/h) can be used for:<\/strong><\/p>\n<ul>\n<li>The supply of boilers in single-family houses.<\/li>\n<li>Community of neighbors buildings<\/li>\n<li>Small installations.<\/li>\n<\/ul>\n<p><strong>And large units (from 2,000l\/h to 12,000l\/h) can be applied in:<\/strong><\/p>\n<ul>\n<li>Large buildings requiring 24h\/7 electricity<\/li>\n<li>Data Centers<\/li>\n<li>Hospitals<\/li>\n<li>Airports<\/li>\n<li>Malls&#8230;<\/li>\n<\/ul>\n<h3><strong>Applications &amp; Specific Features<\/strong><\/h3>\n<ul>\n<li>Multiple burner, appliances or service tanks supplied with one GP pressure unit.<\/li>\n<li>Appliances installed at different heights.<\/li>\n<li>Modulating burners when using the Inpro Oil Burner Inlet Assembly (<a href=\"https:\/\/www.inprord.com\/archivos\/2-Pressure%20reducing%20valves%20and%20burner%20inlet%20assemblies%20EN.pdf\" target=\"_blank\" rel=\"noopener\">see Datasheet<\/a>).<\/li>\n<li>Oil Supply installation using \u2018dead leg\u2019 pipework. GP unit does not need external controls.<\/li>\n<li>GP units operate on an internal pressure switch only pumping fuel when required.<\/li>\n<li>Pressure regulators may be required at oil inlet to burners\/appliances.<\/li>\n<li>Limited suction lift may require GP unit to be sited near the oil tank.<\/li>\n<\/ul>\n<h3><strong>Accessories and Adaptations Art. Nr.<\/strong><\/h3>\n<ul>\n<li>Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).<\/li>\n<li>GSM alarm system by SMS messages, or connection to modem. \u00a0Adaptation of Pressure Group for high pressure, working conditions of up to 6 Kg\/cm2<\/li>\n<li>Leak collector trays with infrared detectors (standard in GP-800 and GP-1500).<\/li>\n<li>Modifications to adapt to specifically regulated environments with tropicalised equipment or ATEX.<\/li>\n<li>Solenoid valves with f<\/li>\n<\/ul>\n<div>\n<div><\/div>\n<div>\n<div>\n<h3><strong>Benefits and advantages of the GP-GE High Pressure<\/strong><\/h3>\n<ul>\n<li>\n<div>\n<div>\n<p>Single-pipe installation with automatic pressure-controlled operation on demand: Lower installation costs, as no electrical connection to the point(s) of consumption is required.<\/p>\n<\/div>\n<\/div>\n<\/li>\n<li>\n<div>\n<div>\n<p>Designed for high-pressure operation: Specifically configured for installations requiring higher fuel supply pressures.<\/p>\n<\/div>\n<\/div>\n<\/li>\n<li>\n<div>\n<div>\n<p>Twin-pump system: Duplicates critical components to increase equipment reliability and redundancy.<\/p>\n<\/div>\n<\/div>\n<\/li>\n<li>\n<div>\n<div>\n<p>Different fuel transfer capacities: Available in various models to match the flow rate to the requirements of each installation.<\/p>\n<\/div>\n<\/div>\n<\/li>\n<li>\n<div>\n<div>\n<p>Compatible with diesel and HVO: Designed to transfer both fuels from the main storage tank to the different points of consumption.<\/p>\n<\/div>\n<\/div>\n<\/li>\n<li>\n<div>\n<div>\n<p>Adaptable to demanding installations: Can incorporate ATEX configurations, tropicalisation, IP55 weatherproof enclosures, soundproofing and infrared spill detection, depending on project requirements.<\/p>\n<\/div>\n<\/div>\n<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<h3><strong> Technical Features<\/strong><\/h3>\n<table class=\"t_modelos\" style=\"width: 87.9393%; height: 397px;\">\n<tbody>\n<tr style=\"height: 27px;\">\n<th style=\"width: 35.4895%; height: 27px;\" colspan=\"2\"><span style=\"font-weight: 500;\">MODEL<\/span><\/th>\n<th style=\"width: 15.035%; height: 27px;\"><span style=\"font-weight: 500;\">GP-300 N\/GE<\/span><\/th>\n<th style=\"width: 15.035%; height: 27px;\"><span style=\"font-weight: 500;\">GP-500 N\/GE<\/span><\/th>\n<th style=\"width: 15.035%; height: 27px;\"><span style=\"font-weight: 500;\">GP-800 N\/GE<\/span><\/th>\n<th style=\"width: 16.7832%; height: 27px;\"><span style=\"font-weight: 500;\">GP-1.500 N\/GE<\/span><\/th>\n<\/tr>\n<tr style=\"height: 27px;\">\n<th style=\"width: 23.2517%; height: 27px;\"><span style=\"font-weight: 500;\">FLOW<\/span><\/th>\n<th style=\"width: 12.2378%; height: 27px;\"><span style=\"font-weight: 500;\">l\/h<\/span><\/th>\n<td style=\"width: 15.035%; height: 27px;\">300<\/td>\n<td style=\"width: 15.035%; height: 27px;\">500<\/td>\n<td style=\"width: 15.035%; height: 27px;\">800<\/td>\n<td style=\"width: 16.7832%; height: 27px;\">1500<\/td>\n<\/tr>\n<tr style=\"height: 50px;\">\n<th style=\"width: 23.2517%; height: 100px;\" rowspan=\"2\"><span style=\"font-weight: 500;\">CONNECTION TO<br \/>\nTHE HYDRAULIC<br \/>\nCIRCUIT<br \/>\n(\u00d8 THREAD \/ \u00d8 MM)<\/span><\/th>\n<th style=\"width: 12.2378%; height: 50px;\"><span style=\"font-weight: 500;\">SUCTION<\/span><\/th>\n<td style=\"width: 15.035%; height: 50px;\">3\/4\u201d<\/td>\n<td style=\"width: 15.035%; height: 50px;\">3\/4\u201d<\/td>\n<td style=\"width: 15.035%; height: 50px;\">1\u201d<\/td>\n<td style=\"width: 16.7832%; height: 50px;\">1\u201d<\/td>\n<\/tr>\n<tr style=\"height: 50px;\">\n<th style=\"width: 12.2378%; height: 50px;\"><span style=\"font-weight: 500;\">DRIVE<\/span><\/th>\n<td style=\"width: 15.035%; height: 50px;\">1\/2\u201d<\/td>\n<td style=\"width: 15.035%; height: 50px;\">1\/2\u201d<\/td>\n<td style=\"width: 15.035%; height: 50px;\">1\/2\u201d<\/td>\n<td style=\"width: 16.7832%; height: 50px;\">3\/4\u201d<\/td>\n<\/tr>\n<tr style=\"height: 27px;\">\n<th style=\"width: 23.2517%; height: 27px;\"><span style=\"font-weight: 500;\">POWER SUPPLY<\/span><\/th>\n<th style=\"width: 12.2378%; height: 27px;\"><span style=\"font-weight: 500;\">VOLTS<\/span><\/th>\n<td style=\"width: 15.035%; height: 27px;\">230\/400<\/td>\n<td style=\"width: 15.035%; height: 27px;\">230\/400<\/td>\n<td style=\"width: 15.035%; height: 27px;\">230\/400<\/td>\n<td style=\"width: 16.7832%; height: 27px;\">230\/400<\/td>\n<\/tr>\n<tr style=\"height: 27px;\">\n<th style=\"width: 23.2517%; height: 54px;\" rowspan=\"2\"><span style=\"font-weight: 500;\">MOTOR<br \/>\nPOWER<\/span><\/th>\n<th style=\"width: 12.2378%; height: 27px;\"><span style=\"font-weight: 500;\">C.V.<\/span><\/th>\n<td style=\"width: 15.035%; height: 27px;\">1\/2<\/td>\n<td style=\"width: 15.035%; height: 27px;\">1\/2<\/td>\n<td style=\"width: 15.035%; height: 27px;\">3\/4<\/td>\n<td style=\"width: 16.7832%; height: 27px;\">1\u00bd<\/td>\n<\/tr>\n<tr style=\"height: 27px;\">\n<th style=\"width: 12.2378%; height: 27px;\"><span style=\"font-weight: 500;\">KW<\/span><\/th>\n<td style=\"width: 15.035%; height: 27px;\">0,25<\/td>\n<td style=\"width: 15.035%; height: 27px;\">0,37<\/td>\n<td style=\"width: 15.035%; height: 27px;\">0,55<\/td>\n<td style=\"width: 16.7832%; height: 27px;\">1,1<\/td>\n<\/tr>\n<tr style=\"height: 53px;\">\n<th style=\"width: 23.2517%; height: 53px;\"><span style=\"font-weight: 500;\">MAX.<br \/>\nPRESSURE<\/span><\/th>\n<th style=\"width: 12.2378%; height: 53px;\"><span style=\"font-weight: 500;\">Kg\/cm2<\/span><\/th>\n<td style=\"width: 15.035%; height: 53px;\">20<\/td>\n<td style=\"width: 15.035%; height: 53px;\">20<\/td>\n<td style=\"width: 15.035%; height: 53px;\">20<\/td>\n<td style=\"width: 16.7832%; height: 53px;\">20<\/td>\n<\/tr>\n<tr style=\"height: 53px;\">\n<th style=\"width: 23.2517%; height: 53px;\"><span style=\"font-weight: 500;\">MOTOR<br \/>\nPROTECTION<\/span><\/th>\n<th style=\"width: 12.2378%; height: 53px;\"><span style=\"font-weight: 500;\">IP<\/span><\/th>\n<td style=\"width: 15.035%; height: 53px;\">55<\/td>\n<td style=\"width: 15.035%; height: 53px;\">55<\/td>\n<td style=\"width: 15.035%; height: 53px;\">55<\/td>\n<td style=\"width: 16.7832%; height: 53px;\">55<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>GP Videos:<\/strong><\/h3>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 50%;\"><strong>\u00a0Pressure switch regulation<\/strong><\/td>\n<td style=\"width: 50%;\">\u00a0<strong>GP troubleshooting<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\"><iframe loading=\"lazy\" src=\"\/\/www.youtube.com\/embed\/NK6ZoEe7wQ8?si=fICi0j-E1RXxIhb1\" width=\"560\" height=\"314\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"><\/iframe><\/td>\n<td style=\"width: 50%;\"><iframe loading=\"lazy\" src=\"\/\/www.youtube.com\/embed\/VFqWAnUEjxc?si=Akx82XeyZmo2KeXR\" width=\"560\" height=\"314\" allowfullscreen=\"allowfullscreen\" data-mce-fragment=\"1\"><\/iframe><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":21382,"template":"","familias_productos":[208],"class_list":["post-12954","productos","type-productos","status-publish","has-post-thumbnail","hentry","familias_productos-oil-transfer-pressure-units"],"acf":{"nombre_producto":"GRUPO PRESI\u00d3N GAS\u00d3LEO MIXTO","documentos":[{"documento":21433,"titulo_documento":"DOWNLOAD DATASHEET EN","descripcion_documento":"","tipo_documento":"1","idioma":""},{"documento":12961,"titulo_documento":"DOWNLOAD DATASHEET FR","descripcion_documento":"","tipo_documento":"1","idioma":""},{"documento":31121,"titulo_documento":"DOWNLOAD MANUAL","descripcion_documento":"","tipo_documento":"2","idioma":""}],"imagenes":null,"videos":[{"url_video":"https:\/\/youtu.be\/NK6ZoEe7wQ8?si=fICi0j-E1RXxIhb1"},{"url_video":"https:\/\/youtu.be\/VFqWAnUEjxc?si=Akx82XeyZmo2KeXR"}],"faqs":null,"referencia_a3":"","no_visible_en_web":false},"_links":{"self":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/12954","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos"}],"about":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/types\/productos"}],"version-history":[{"count":5,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/12954\/revisions"}],"predecessor-version":[{"id":37588,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/12954\/revisions\/37588"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/media\/21382"}],"wp:attachment":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/media?parent=12954"}],"wp:term":[{"taxonomy":"familias_productos","embeddable":true,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/familias_productos?post=12954"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}