{"id":12967,"date":"2021-11-16T08:45:45","date_gmt":"2021-11-16T08:45:45","guid":{"rendered":"https:\/\/www.inprogroup.net\/productos\/gp-gc\/"},"modified":"2026-04-27T12:39:46","modified_gmt":"2026-04-27T12:39:46","slug":"gp-gc","status":"publish","type":"productos","link":"https:\/\/www.inprord.com\/en\/products\/gp-gc\/","title":{"rendered":"05. GP-GC"},"content":{"rendered":"<h2><strong>OIL TRANSFER PRESSURE UNITS- HIGH FLOW SYSTEMS- From 2,000 l\/h to 12,000l\/h\u00a0<\/strong><\/h2>\n<h3><strong>1 pump- 2 pumps<\/strong><\/h3>\n<p>Inpro pressure units are equipment used to transfer liquid fuel such as diesel or HVO from a main tank to different consumption points through the pressurization of a line, for the supply of machinery that requires these fuels, such as generators (power generators) or burners for boilers in buildings.<\/p>\n<h6><span style=\"color: #ffffff;\">.<\/span><\/h6>\n<p>There are several sizes and configurations of equipment, in which the flow rate that can control the equipment can vary (from 30l\/h to 12,000 l\/h), the maximum pressure at which they can work, with the possibility of redundancy in some components, and other parameters such as the type of power supply.<\/p>\n<h6><span style=\"color: #ffffff;\">.<\/span><\/h6>\n<p>It can be Normal or Twin equipment that duplicates critical components to increase reliability.<\/p>\n<ul>\n<li>Gas threaded flange DIN-2576 PN-1<\/li>\n<li><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">For high flow rates from 2,200 l\/h to 12,000 l\/h.<\/span><\/li>\n<li>Perfect for critical facilities such as airports, hospitals or Data Centers.<\/li>\n<li>2 pumps skid possibility that duplicates critical components to increase reliability.<\/li>\n<li><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">Includes an infrared leak detection system.<\/span><\/li>\n<li><span class=\"OYPEnA text-decoration-none text-strikethrough-none\">6 signals output for reporting status and alarms to central BMS<\/span><\/li>\n<\/ul>\n<h3><strong>\u00a0Application area e<\/strong><strong>xample<\/strong><\/h3>\n<p><strong>Small units (from 30l\/h to 1,500l\/h) can be used for:<\/strong><\/p>\n<ul>\n<li>The supply of boilers in single-family houses.<\/li>\n<li>Community of neighbors buildings<\/li>\n<li>Small installations.<\/li>\n<\/ul>\n<p><strong>And large units (from 2,000l\/h to 12,000l\/h) can be applied in:<\/strong><\/p>\n<ul>\n<li>Large buildings requiring 24h\/7 electricity<\/li>\n<li>Data Centers<\/li>\n<li>Hospitals<\/li>\n<li>Airports<\/li>\n<li>Malls&#8230;<\/li>\n<\/ul>\n<h3><strong>Applications &amp; Specific Features<\/strong><\/h3>\n<ul>\n<li>Multiple burner, appliances or service tanks supplied with one GP pressure unit.<\/li>\n<li>Appliances installed at different heights.<\/li>\n<li>Modulating burners when using the Inpro Oil Burner Inlet Assembly (<a href=\"https:\/\/www.inprord.com\/archivos\/2-Pressure%20reducing%20valves%20and%20burner%20inlet%20assemblies%20EN.pdf\" target=\"_blank\" rel=\"noopener\">see Datasheet<\/a>).<\/li>\n<li>Oil Supply installation using \u2018dead leg\u2019 pipework. GP unit does not need external controls.<\/li>\n<li>GP units operate on an internal pressure switch only pumping fuel when required.<\/li>\n<li>Pressure regulators may be required at oil inlet to burners\/appliances.<\/li>\n<li>Limited suction lift may require GP unit to be sited near the oil tank.<\/li>\n<\/ul>\n<h3><strong>Accessories and Adaptations<\/strong><\/h3>\n<ul>\n<li>Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).<\/li>\n<li>GSM alarm system by SMS messages, or connection to modem.<\/li>\n<li>Adaptation of Pressure Group for high pressure, working conditions of up to 6 Kg\/cm2<\/li>\n<li>Leak collector trays with infrared detectors (standard in GP-800 and GP-1500).<\/li>\n<li>Modifications to adapt to specifically regulated environments with tropicalised equipment or ATEX.<\/li>\n<li>Solenoid valve<\/li>\n<\/ul>\n<h3><strong>Technical Features<\/strong><\/h3>\n<table class=\"t_modelos\">\n<tbody>\n<tr>\n<th colspan=\"2\">MODEL<\/th>\n<th>GP-2200 NT<br \/>\nGP-2200 GE<\/th>\n<th>GP-3200 NT<br \/>\nGP-3200 GE<\/th>\n<th>GP-4200 NT<br \/>\nGP-4200 GE<\/th>\n<th>GP-6500 NT<br \/>\nGP-6500 GE<\/th>\n<th>GP-8500 NT<br \/>\nGP-8500 GE<\/th>\n<th>GP-12000 NT<br \/>\nGP-12000 GE<\/th>\n<\/tr>\n<tr>\n<th>FLOW<\/th>\n<th>l\/h<\/th>\n<td>2200<\/td>\n<td>3200<\/td>\n<td>4200<\/td>\n<td>6500<\/td>\n<td>8500<\/td>\n<td>12000<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"2\">CONNECTION TO THE<br \/>\nHYDRAULIC CIRCUIT<br \/>\n(\u00d8 THREAD \/ \u00d8 mm)<\/th>\n<th>SUCTION<\/th>\n<td>1\u201d F<\/td>\n<td>1\u201d 1\/2 F<\/td>\n<td>1\u201d 1\/2 F<\/td>\n<td>2\u201d F<\/td>\n<td>2\u201d F<\/td>\n<td>2\u201d F<\/td>\n<\/tr>\n<tr>\n<th>DRIVE<\/th>\n<td>3\/4\u201d F<\/td>\n<td>1\u201d F<\/td>\n<td>1\u201d 1\/4 F<\/td>\n<td>1\u201d 1\/2 F<\/td>\n<td>1\u201d 1\/2 F<\/td>\n<td>2\u201d F<\/td>\n<\/tr>\n<tr>\n<th>POWER SUPPLY<\/th>\n<th>VOLTS<\/th>\n<td>230\/400<br \/>\ntri-phase<\/td>\n<td>230\/400<br \/>\ntri-phase<\/td>\n<td>230\/400<br \/>\ntri-phase<\/td>\n<td>230\/400<br \/>\ntri-phase<\/td>\n<td>230\/400<br \/>\ntri-phase<\/td>\n<td>230\/400<br \/>\ntri-phase<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"2\">MOTOR POWER<\/th>\n<th>C.V.<\/th>\n<td>2<\/td>\n<td>2<\/td>\n<td>3<\/td>\n<td>4<\/td>\n<td>4<\/td>\n<td>5,5<\/td>\n<\/tr>\n<tr>\n<th>KW<\/th>\n<td>1,5<\/td>\n<td>1,5<\/td>\n<td>2,2<\/td>\n<td>3<\/td>\n<td>3<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th>MAX. PRESSURE<\/th>\n<th>kg\/cm2<\/th>\n<td>3,5<\/td>\n<td>3,5<\/td>\n<td>3,5<\/td>\n<td>3,5<\/td>\n<td>4<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th>SAFETY VALVE OPENS AT:<\/th>\n<th>kg\/cm2<\/th>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\" rowspan=\"1\">PIPPING SUCT\/PRES<\/th>\n<td>1\u00bd\u201d \/ 1\u201d<\/td>\n<td>2\u201d \/ 1\u00bc\u201d<\/td>\n<td>2\u00bd\u201d \/ 1\u00bd\u201d<\/td>\n<td>2\u00bd\u201d \/ 1\u00bd\u201d<\/td>\n<td>3\u201d \/ 2\u201d<\/td>\n<td>3\u201d \/ 2\u00bd\u201d<\/td>\n<\/tr>\n<tr>\n<th>MOTOR PROTECTION<\/th>\n<th>IP<\/th>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&#8211; Sound Level: 60 dB (A)<\/p>\n<p><span style=\"font-size: 8pt;\"><span style=\"color: #ffffff;\">\u00a0GP-GC GP GC\u00a0 \u00a0<\/span><span style=\"color: #ffffff;\">GPGC<\/span><\/span><\/p>\n<h3>3D Pictures<\/h3>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img002-e1693571423988.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-18109 size-medium\" src=\"https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img002-e1693571423988-244x300.png\" alt=\"\" width=\"244\" height=\"300\" srcset=\"https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img002-e1693571423988-244x300.png 244w, https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img002-e1693571423988-834x1024.png 834w, https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img002-e1693571423988-768x943.png 768w, https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img002-e1693571423988.png 880w\" sizes=\"(max-width: 244px) 100vw, 244px\" \/><\/a><a href=\"https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img001-e1693571466432.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-18106 size-medium\" src=\"https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img001-e1693571466432-234x300.png\" alt=\"\" width=\"234\" height=\"300\" srcset=\"https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img001-e1693571466432-234x300.png 234w, https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img001-e1693571466432-800x1024.png 800w, https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img001-e1693571466432-768x983.png 768w, https:\/\/www.inprord.com\/wp-content\/uploads\/2021\/11\/Bastidor_GGCaudal_A_img001-e1693571466432.png 844w\" sizes=\"(max-width: 234px) 100vw, 234px\" \/><\/a><\/p>\n<h3>3D V\u00eddeo Animation<\/h3>\n<p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/yYBUGiCE7g4?si=k4ReOrqj5pXneHQ6\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n","protected":false},"featured_media":18944,"template":"","familias_productos":[208],"class_list":["post-12967","productos","type-productos","status-publish","has-post-thumbnail","hentry","familias_productos-oil-transfer-pressure-units"],"acf":{"nombre_producto":"GRUPO PRESI\u00d3N GAS\u00d3LEO GRAN CAUDAL","documentos":[{"documento":35560,"titulo_documento":"DOWNLOAD DATASHEET EN","descripcion_documento":"","tipo_documento":"1","idioma":""},{"documento":12974,"titulo_documento":"DOWNLOAD DATASHEET FR","descripcion_documento":"","tipo_documento":"1","idioma":""},{"documento":31121,"titulo_documento":"DOWNLOAD MANUAL","descripcion_documento":"","tipo_documento":"2","idioma":""},{"documento":23072,"titulo_documento":"GP-GPS Design Questionnaire","descripcion_documento":"","tipo_documento":"1","idioma":""}],"imagenes":[{"imagen":18113,"descripcion_imagen":""},{"imagen":18116,"descripcion_imagen":""},{"imagen":18128,"descripcion_imagen":""}],"videos":null,"faqs":null,"referencia_a3":"","no_visible_en_web":false},"_links":{"self":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/12967","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos"}],"about":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/types\/productos"}],"version-history":[{"count":8,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/12967\/revisions"}],"predecessor-version":[{"id":35569,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/12967\/revisions\/35569"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/media\/18944"}],"wp:attachment":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/media?parent=12967"}],"wp:term":[{"taxonomy":"familias_productos","embeddable":true,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/familias_productos?post=12967"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}