{"id":13020,"date":"2021-11-16T08:45:49","date_gmt":"2021-11-16T08:45:49","guid":{"rendered":"https:\/\/www.inprogroup.net\/productos\/fp-nge-bio\/"},"modified":"2024-05-20T10:52:06","modified_gmt":"2024-05-20T10:52:06","slug":"fp-nge-bio","status":"publish","type":"productos","link":"https:\/\/www.inprord.com\/en\/products\/fp-nge-bio\/","title":{"rendered":"FP N\/GE BIO FUEL TRANSFER SKID TO DAY TANKS"},"content":{"rendered":"<h3>Applications &amp; Specific Features<\/h3>\n<ul>\n<li>Main tank to daily service tank oil transfer.<\/li>\n<li>Oil supply to one or multiple generators.<\/li>\n<li>Installations with large height differences between main storage and daily service tanks.<\/li>\n<li>Any oil supply for \u2018tank to tank\u2019 automated by a signal from the daily tank level switch to the FP unit.<\/li>\n<li>Special FP units available for aggressive or heated non standard fuels.<\/li>\n<\/ul>\n<h3>Accessories and adaptations<\/h3>\n<ul>\n<li>Special non \u2013ferrous metal free versions upon request.<\/li>\n<li>Standard motor power ready for viscosities till 38mm2\/s (40\u00baC). For other, please consult.<\/li>\n<li>Oil failure control system, to protect gears running with an empty tank.<\/li>\n<li>Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).<\/li>\n<li>GSM alarm system by SMS messages, or connection to modem.<\/li>\n<li>Adaptation of Pressure Group for high pressure, working conditions above 4,5 Kg\/cm2.<\/li>\n<li>Leak collector trays with infrared detectors (standard in RL 4 and above).<\/li>\n<li>Modifications to adapt to specifically regulated environments (tropicalised equipment or ATEX).<\/li>\n<li>Solenoid valves with flow limiters, to automate fi<br \/>\n<table class=\"t_modelos\">\n<tbody>\n<tr>\n<th colspan=\"2\">MODEL<\/th>\n<th>FP 10<\/th>\n<th>FP 23<\/th>\n<th>FP 41<\/th>\n<th>FP 90<\/th>\n<th>FP 120<\/th>\n<th>FP 240<\/th>\n<th>FP 360<\/th>\n<th>FP 570<\/th>\n<\/tr>\n<tr>\n<th>MAX. FLOW<\/th>\n<th>l\/h<\/th>\n<td>100<\/td>\n<td>260<\/td>\n<td>460<\/td>\n<td>900<\/td>\n<td>1400<\/td>\n<td>2100<\/td>\n<td>3400<\/td>\n<td>5300<\/td>\n<\/tr>\n<tr>\n<th>SUPPLY<br \/>\nVOLTAGE<\/th>\n<th>VOLT<\/th>\n<td>400*<\/td>\n<td>400*<\/td>\n<td>400*<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<td>400<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"2\">MOTOR<br \/>\nPOWER<\/th>\n<th>KW<\/th>\n<td>0,25<\/td>\n<td>0,25<\/td>\n<td>0,25<\/td>\n<td>0,55<\/td>\n<td>0,55<\/td>\n<td>2,2<\/td>\n<td>3<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<th>CV<\/th>\n<td>1\/3<\/td>\n<td>1\/3<\/td>\n<td>1\/3<\/td>\n<td>3\/4<\/td>\n<td>3\/4<\/td>\n<td>3<\/td>\n<td>4<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th>MOTOR<\/th>\n<th>r.p.m<\/th>\n<td>1400<\/td>\n<td>1400<\/td>\n<td>1400<\/td>\n<td>1400<\/td>\n<td>1400<\/td>\n<td>1400<\/td>\n<td>1400<\/td>\n<td>1400<\/td>\n<\/tr>\n<tr>\n<th>SECURITY VALVE<br \/>\nOPENS AT<\/th>\n<th>bar<\/th>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<td>4,5<\/td>\n<\/tr>\n<tr>\n<th rowspan=\"3\">CONNECTION TO<br \/>\nTHE HYDRAULIC<br \/>\nCIRCUIT<\/th>\n<th>SUCTION<\/th>\n<td>1\u201d F<\/td>\n<td>1\u201d F<\/td>\n<td>1\u201d F<\/td>\n<td>DN 32<\/td>\n<td>DN 32<\/td>\n<td>DN 50<\/td>\n<td>DN 50<\/td>\n<td>DN 50<\/td>\n<\/tr>\n<tr>\n<th>DRIVE<\/th>\n<td>1\u201d F<\/td>\n<td>1\u201d F<\/td>\n<td>1\u201d F<\/td>\n<td>DN 32<\/td>\n<td>DN 32<\/td>\n<td>DN 50<\/td>\n<td>DN 50<\/td>\n<td>DN 50<\/td>\n<\/tr>\n<tr>\n<th>OVERPRESSURE<\/th>\n<td>3\/4\u201d F<\/td>\n<td>3\/4\u201d F<\/td>\n<td>3\/4\u201d F<\/td>\n<td>1\u201d F<\/td>\n<td>1\u201d F<\/td>\n<td>DN 40<\/td>\n<td>DN 40<\/td>\n<td>DN 40<\/td>\n<\/tr>\n<tr>\n<th>MOTOR<br \/>\nPROTECTION<\/th>\n<th>IP<\/th>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<td>55<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>(*) Also available in 230 single phase versions (W\/WD= 230 V. single phase version; D= 400 V. triphase versions).<br \/>\n&#8211; For other capacity and mediums, please consult.<br \/>\n&#8211; ZW: Two pumps versions<br \/>\n1)For viscosities till 38 mm2\/s (40\u00baC)<\/li>\n<\/ul>\n","protected":false},"featured_media":25542,"template":"","familias_productos":[203,210],"class_list":["post-13020","productos","type-productos","status-publish","has-post-thumbnail","hentry","familias_productos-liquid-fuel-transfer","familias_productos-oil-transf-to-daily-tanks-pressure-units"],"acf":{"nombre_producto":"FP TANK TO TANK TRANSFERRING FP ONE PUMP-FP ZW TWO PUMPS Versions for Bio Fuel","documentos":[{"documento":21343,"titulo_documento":"DOWNLOAD DATASHEET EN","descripcion_documento":"","tipo_documento":"1","idioma":"2"},{"documento":13027,"titulo_documento":"DOWNLOAD DATASHEET FR","descripcion_documento":"","tipo_documento":"1","idioma":"4"}],"imagenes":[{"imagen":20542,"descripcion_imagen":""},{"imagen":20538,"descripcion_imagen":""}],"videos":null,"faqs":null,"referencia_a3":"","no_visible_en_web":false},"_links":{"self":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/13020","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos"}],"about":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/types\/productos"}],"version-history":[{"count":3,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/13020\/revisions"}],"predecessor-version":[{"id":24566,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/productos\/13020\/revisions\/24566"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/media\/25542"}],"wp:attachment":[{"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/media?parent=13020"}],"wp:term":[{"taxonomy":"familias_productos","embeddable":true,"href":"https:\/\/www.inprord.com\/en\/wp-json\/wp\/v2\/familias_productos?post=13020"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}